Victron Energy Smart BatteryProtect Marin batteriladdare

5

Victron Energy Smart BatteryProtect Marin batteriladdare

5
Protects the battery against excessive discharge and can be used as a system on/off switchThe Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off...
Läs mer
I lager för webbutik 2 st.
Skickas imorgon ,
2024-11-22
Nu bara 1,794,55 kr med kod BLACK5
1,889 kr
2,361,97 kr
- 20 %
Marin batteriladdare Victron Energy Smart BatteryProtect Marin batteriladdare

Victron Energy Smart BatteryProtect Marin batteriladdare

1,889 kr
2,361,97 kr
- 20 %

Produktkod: BPR110048000 | ID: 393376

Victron Energy Smart BatteryProtect Marin batteriladdare

Protects the battery against excessive discharge and can be used as a system on/off switch
The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch.

12/24 V auto ranging
The Smart BatteryProtect automatically detects system voltage one time only.

Bluetooth: programming made easy
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled.

A special setting for Li-ion batteries
In this mode the BatteryProtect can be controlled by the VE.Bus BMS.
Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra-low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown. 

Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3 V respectively 32.6 V.

Ignition proof
No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

Strömförsörjning

Spänning

Ström

100 A

Land

Tillverkad i

Nederländerna

5 / 5

Baserat på antalet omdömen: 7

5 7
4 0
3 0
2 0
1 0

Alla recensioner kommer från verifierade kunder som har köpt en produkt från oss tidigare.

Z

Zoltánné P.

hu Flagga

Ungern

27.09.2023

Teszi a dolgát.

Automatiserad översättning

Denna recension kan inte översättas.
J

Joško P.

hr Flagga

Kroatien

31.03.2023

S

Srećko S.

hr Flagga

Kroatien

19.12.2022

Everything is superb.

Automatiserad översättning

Denna recension kan inte översättas.
S

Srećko S.

hr Flagga

Kroatien

19.12.2022

Everything is superb.

Automatiserad översättning

Denna recension kan inte översättas.
I

IVA P.

bg Flagga

Bulgarien

17.12.2022

Добра цена от Музикер

Automatiserad översättning

Denna recension kan inte översättas.